MDT Ld, 4su Mdrc, 16a, 230vac, C-Load, 140?f Aks-0416.03"

Manufacturer-number: AKS-0416.03 - The version of this item is changing. When ordering youll automatically receive the new version:- Switch Actuator with bistable relays.- Current max. 16A, capacitive load max. 140µF- Space saving by ideal form factor- Extensive function extension- Lockable manual operation and LED indicator for each channel- NO and NC contact operation- Status response at manually operation- Time functions (switch-on/switch-off delay, staircase light functions)- Extended logical and scene functions for each channel- Extended status functions (inverted, cyclic, at block)- Treshold switch (Byte/2Byte/2Byte float)- Hour meter for switching- Priority/forced operation with automatic release time- Separate power supply terminals for each channel- Power supply via KNX bus- Integrated bus coupling unit Switch Actuator with bistable relays, Current max. 16A, capacitive load max. 140µF, Space saving by ideal form factor, Push Button and LED indicator for each channel, NO and NC contact operation, Status response after manually operation, Time functions (switch-on/switch-off delay, staircase light function), Status response (active/passive) for each channel, Logical linking of binary data, 8 scenes per channel, Central switching functions and block functions, Programmable behavior in case of bus voltage failure or return, Separate power supply terminals for each channel,Power supply via KNX bus, Modular installation device for DIN 35mm rails, Integrated bus coupling unit. photographed by EIB3D.COM Standard Switch Actuator with bistable relays, Current max. 16A, capacitive load max. 140?F, Space saving by ideal form factor, Push Button and LED indicator for each channel, NO and NC contact operation, Time functions (switch-on/switch-off delay, staircase light function), Status response (active/passive) for each channel, Logical linking of binary data, 8 scenes per channel, Central switching functions and block functions, Programmable behaviour in case of bus voltage failure or return, Each contact has an own supply phase, Power supply via KNX bus, Modular installation device for DIN 35mm rails, Integrated bus coupling unit.Note:After registration and login, all costs (also discounts) arising for you will be clearly shown in the cart (over the icon cart) depending on the payment methods, shipping methods and order amounts you have selected as well as your country and address. - AKS-0416.03

Ld, 4su Mdrc, 16a, 230vac, C-Load, 140?f - Aks-0416.03"

150,54
Dit product is momenteel niet beschikbaar
Vergelijkbaar product: Nordväl DashCam DC101-2K Bekijken...
Bekijk alle vergelijkbare producten
Categorie Installation bus
Merk MDT
Vroeg een vraag toe

Reviews
Geen reviews gevonden